SSACLI  Status

 

Start des ssacli Programs:

 

# ssacli
Smart Storage Administrator CLI 5.20.8.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.

=>

Der Interaktive modus ist damit gestartet.


 

Abfrage welcher Controller eingebaut ist:

 

=> ctrl all show

Smart Array P440ar in Slot 0 (Embedded)   (sn: PDNLH0BRH238AA)

 

=> ctrl all show status

Smart Array P440ar in Slot 0 (Embedded)
   Controller Status: OK
   Cache Status: Not Configured
   Battery/Capacitor Status: Recharging

 

Es gibt also ein P440ar Adapter im Slot 0.

Dess Einstellung kann man mit dem folgenden Befehl abfragen:

=> ctrl slot=0 show

Smart Array P440ar in Slot 0 (Embedded)
   Bus Interface: PCI
   Slot: 0
   Serial Number: PDNLH0BRH238AA
   Cache Serial Number: PDNLH0BRH238AA
   RAID 6 Status: Enabled
   Controller Status: OK
   Hardware Revision: B
   Firmware Version: 7.00
   Firmware Supports Online Firmware Activation: False
   Rebuild Priority: High
   Expand Priority: Medium
   Surface Scan Delay: 3 secs
   Surface Scan Mode: Idle
   Parallel Surface Scan Supported: Yes
   Current Parallel Surface Scan Count: 1
   Max Parallel Surface Scan Count: 16
   Queue Depth: Automatic
   Monitor and Performance Delay: 60  min
   Elevator Sort: Enabled
   Degraded Performance Optimization: Disabled
   Inconsistency Repair Policy: Disabled
   Wait for Cache Room: Disabled
   Surface Analysis Inconsistency Notification: Disabled
   Post Prompt Timeout: 15 secs
   Cache Board Present: True
   Cache Status: Not Configured
   Drive Write Cache: Disabled
   Total Cache Size: 2.0
   Total Cache Memory Available: 1.8
   Battery Backed Cache Size: 1.8
   No-Battery Write Cache: Disabled
   SSD Caching RAID5 WriteBack Enabled: True
   SSD Caching Version: 2
   Cache Backup Power Source: Batteries
   Battery/Capacitor Count: 1
   Battery/Capacitor Status: Recharging
   SATA NCQ Supported: True
   Spare Activation Mode: Activate on physical drive failure (default)
   Controller Temperature (C): 38
   Cache Module Temperature (C): 32
   Number of Ports: 2 Internal only
   Encryption: Not Set
   Express Local Encryption: False
   Driver Name: hpsa
   Driver Version: 3.4.14
   Driver Supports SSD Smart Path: True
   PCI Address (Domain:Bus:Device.Function): 0000:03:00.0
   Negotiated PCIe Data Rate: PCIe 1.0 x8 (2000 MB/s)
   Controller Mode: RAID
   Pending Controller Mode: RAID
   Port Max Phy Rate Limiting Supported: False
   Latency Scheduler Setting: Disabled
   Current Power Mode: MaxPerformance
   Survival Mode: Enabled
   Host Serial Number: CZJ7491R21
   Sanitize Erase Supported: True
   Primary Boot Volume: None
   Secondary Boot Volume: None

 

Abfrage der Enclosures:

 

=> controller slot=0 enclosure all show


Smart Array P440ar in Slot 0 (Embedded)

   Internal Drive Cage at Port 1I, Box 0, OK


   Internal Drive Cage at Port 2I, Box 3, OK

 

Ebenso die Ports:

 

=> controller slot=0 port all show

Smart Array P440ar in Slot 0 (Embedded)
   Port Name: 1I
   Port Name: 2I

 

Und deren Details:

 

=> controller slot=0 port 1I show

Smart Array P440ar in Slot 0 (Embedded)
   Port Name: 1I
         Port ID: 0
         Port Connection Number: 0
         SAS Address: 5001438038803DF0
         Port Location: Internal
         Port Phy Count: 4

=> controller slot=0 port 2I show

Smart Array P440ar in Slot 0 (Embedded)
   Port Name: 2I
         Port ID: 1
         Port Connection Number: 1
         SAS Address: 5001438038803DF4
         Port Location: Internal
         Port Phy Count: 4

 

 

Man kann auch den Setup im Bezug zu den Platten abfragen:

 

=>  ctrl all show config

Smart Array P440ar in Slot 0 (Embedded)   (sn: PDNLH0BRH238AA)


   Internal Drive Cage at Port 1I, Box 0, OK


   Internal Drive Cage at Port 2I, Box 3, OK


   Port Name: 1I

   Port Name: 2I

   Array A (SAS, Unused Space: 1614505  MB)

      logicaldrive 1 (50.00 GB, RAID 1, OK)

      physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
      physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)

   Unassigned

      physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SAS HDD, 300 GB, OK)
      physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SAS HDD, 300 GB, OK)

 

 


 

Nun erfolgt die Abfrage nach den installierten Platten:

 

=>  ctrl slot=0 pd all show

Smart Array P440ar in Slot 0 (Embedded)

   Array A

      physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
      physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)

   Unassigned

      physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SAS HDD, 300 GB, OK)
      physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SAS HDD, 300 GB, OK)

 

Es sind 4 Platten (physicaldrive) eingebaut, zwei mit 900GB und zwei mit 300GB.

Die 900GB Platten sind in einem Verbund (Array A) zusammengefasst und die 300GB sind noch ungenutzt (Unassigned).

Oder auch nur die Status Abfrage:

 

=> ctrl slot=0 pd all show status

   physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 900 GB): OK
   physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 900 GB): OK
   physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 300 GB): OK
   physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 300 GB): OK

 

 

Wie ist das Array A aktuell konfiguriert?

=> ctrl slot=0 array A  show


Smart Array P440ar in Slot 0 (Embedded)
   Array: A
      Interface Type: SAS
      Unused Space: 1614505 MB (94.04%)
      Used Space: 100.00 GB (5.96%)
      Status: OK
      MultiDomain Status: OK
      Array Type: Data
      Smart Path: disable

 

Die Nutzung des Speicherplatzes, in From von logicaldrives,  vom Array A soll nun abgefragt werden:

 

=> ctrl slot=0 array A  ld  all show

Smart Array P440ar in Slot 0 (Embedded)

   Array A

      logicaldrive 1 (50.00 GB, RAID 1, OK)

 

Wie sieht das logicaldrive 1 nun genauer aus:

 

=> ctrl slot=0 array A  ld  1 show

Smart Array P440ar in Slot 0 (Embedded)

   Array A

      Logical Drive: 1
         Size: 50.00 GB
         Fault Tolerance: 1
         Heads: 255
         Sectors Per Track: 32
         Cylinders: 12850
         Strip Size: 256 KB
         Full Stripe Size: 256 KB
         Status: OK
         Unrecoverable Media Errors: None
         MultiDomain Status: OK
         Caching:  Disabled
         Unique Identifier: 600508B1001CAD60C51F8F40BBCBECFF
         Disk Name: /dev/sda
         Mount Points: 200 MiB Partition   1, 1024 MiB Partition   2 /boot/efi, /boot
         Disk Partition Information
            Partition   1: Basic, 200 MiB, /boot/efi
            Partition   2: Basic, 1024 MiB, /boot
         Logical Drive Label: 027F0A25PDNLH0BRH2386E5FB6
         Mirror Group 1:
            physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
         Mirror Group 2:
            physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)
         Drive Type: Data
         LD Acceleration Method: All disabled