SSACLI Status
Start des ssacli Programs:
# ssacli
Smart Storage Administrator CLI 5.20.8.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=>
Der Interaktive modus ist damit gestartet.
Abfrage welcher Controller eingebaut ist:
=> ctrl all show
Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH238AA)
=> ctrl all show status
Smart Array P440ar in Slot 0 (Embedded)
Controller Status: OK
Cache Status: Not Configured
Battery/Capacitor Status: Recharging
Es gibt also ein P440ar Adapter im Slot 0.
Dess Einstellung kann man mit dem folgenden Befehl abfragen:
=> ctrl slot=0 show
Smart Array P440ar in Slot 0 (Embedded)
Bus Interface: PCI
Slot: 0
Serial Number: PDNLH0BRH238AA
Cache Serial Number: PDNLH0BRH238AA
RAID 6 Status: Enabled
Controller Status: OK
Hardware Revision: B
Firmware Version: 7.00
Firmware Supports Online Firmware Activation: False
Rebuild Priority: High
Expand Priority: Medium
Surface Scan Delay: 3 secs
Surface Scan Mode: Idle
Parallel Surface Scan Supported: Yes
Current Parallel Surface Scan Count: 1
Max Parallel Surface Scan Count: 16
Queue Depth: Automatic
Monitor and Performance Delay: 60 min
Elevator Sort: Enabled
Degraded Performance Optimization: Disabled
Inconsistency Repair Policy: Disabled
Wait for Cache Room: Disabled
Surface Analysis Inconsistency Notification: Disabled
Post Prompt Timeout: 15 secs
Cache Board Present: True
Cache Status: Not Configured
Drive Write Cache: Disabled
Total Cache Size: 2.0
Total Cache Memory Available: 1.8
Battery Backed Cache Size: 1.8
No-Battery Write Cache: Disabled
SSD Caching RAID5 WriteBack Enabled: True
SSD Caching Version: 2
Cache Backup Power Source: Batteries
Battery/Capacitor Count: 1
Battery/Capacitor Status: Recharging
SATA NCQ Supported: True
Spare Activation Mode: Activate on physical drive failure (default)
Controller Temperature (C): 38
Cache Module Temperature (C): 32
Number of Ports: 2 Internal only
Encryption: Not Set
Express Local Encryption: False
Driver Name: hpsa
Driver Version: 3.4.14
Driver Supports SSD Smart Path: True
PCI Address (Domain:Bus:Device.Function): 0000:03:00.0
Negotiated PCIe Data Rate: PCIe 1.0 x8 (2000 MB/s)
Controller Mode: RAID
Pending Controller Mode: RAID
Port Max Phy Rate Limiting Supported: False
Latency Scheduler Setting: Disabled
Current Power Mode: MaxPerformance
Survival Mode: Enabled
Host Serial Number: CZJ7491R21
Sanitize Erase Supported: True
Primary Boot Volume: None
Secondary Boot Volume: None
Abfrage der Enclosures:
=> controller slot=0 enclosure all show
Smart Array P440ar in Slot 0 (Embedded)
Internal Drive Cage at Port 1I, Box 0, OK
Internal Drive Cage at Port 2I, Box 3, OK
Ebenso die Ports:
=> controller slot=0 port all show
Smart Array P440ar in Slot 0 (Embedded)
Port Name: 1I
Port Name: 2I
Und deren Details:
=> controller slot=0 port 1I show
Smart Array P440ar in Slot 0 (Embedded)
Port Name: 1I
Port ID: 0
Port Connection Number: 0
SAS Address: 5001438038803DF0
Port Location: Internal
Port Phy Count: 4
=> controller slot=0 port 2I show
Smart Array P440ar in Slot 0 (Embedded)
Port Name: 2I
Port ID: 1
Port Connection Number: 1
SAS Address: 5001438038803DF4
Port Location: Internal
Port Phy Count: 4
Man kann auch den Setup im Bezug zu den Platten abfragen:
=> ctrl all show config
Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH238AA)
Internal Drive Cage at Port 1I, Box 0, OK
Internal Drive Cage at Port 2I, Box 3, OK
Port Name: 1I
Port Name: 2I
Array A (SAS, Unused Space: 1614505 MB)
logicaldrive 1 (50.00 GB, RAID 1, OK)
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)
Unassigned
physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SAS HDD, 300 GB, OK)
physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SAS HDD, 300 GB, OK)
Nun erfolgt die Abfrage nach den installierten Platten:
=> ctrl slot=0 pd all show
Smart Array P440ar in Slot 0 (Embedded)
Array A
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)
Unassigned
physicaldrive 2I:3:7 (port 2I:box 3:bay 7, SAS HDD, 300 GB, OK)
physicaldrive 2I:3:8 (port 2I:box 3:bay 8, SAS HDD, 300 GB, OK)
Es sind 4 Platten (physicaldrive) eingebaut, zwei mit 900GB und zwei mit 300GB.
Die 900GB Platten sind in einem Verbund (Array A) zusammengefasst und die 300GB sind noch ungenutzt (Unassigned).
Oder auch nur die Status Abfrage:
=> ctrl slot=0 pd all show status
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 900 GB): OK
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 900 GB): OK
physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 300 GB): OK
physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 300 GB): OK
Wie ist das Array A aktuell konfiguriert?
=> ctrl slot=0 array A show
Smart Array P440ar in Slot 0 (Embedded)
Array: A
Interface Type: SAS
Unused Space: 1614505 MB (94.04%)
Used Space: 100.00 GB (5.96%)
Status: OK
MultiDomain Status: OK
Array Type: Data
Smart Path: disable
Die Nutzung des Speicherplatzes, in From von logicaldrives, vom Array A soll nun abgefragt werden:
=> ctrl slot=0 array A ld all show
Smart Array P440ar in Slot 0 (Embedded)
Array A
logicaldrive 1 (50.00 GB, RAID 1, OK)
Wie sieht das logicaldrive 1 nun genauer aus:
=
> ctrl slot=0 array A ld 1 show
Smart Array P440ar in Slot 0 (Embedded)
Array A
Logical Drive: 1
Size: 50.00 GB
Fault Tolerance: 1
Heads: 255
Sectors Per Track: 32
Cylinders: 12850
Strip Size: 256 KB
Full Stripe Size: 256 KB
Status: OK
Unrecoverable Media Errors: None
MultiDomain Status: OK
Caching: Disabled
Unique Identifier: 600508B1001CAD60C51F8F40BBCBECFF
Disk Name: /dev/sda
Mount Points: 200 MiB Partition 1, 1024 MiB Partition 2 /boot/efi, /boot
Disk Partition Information
Partition 1: Basic, 200 MiB, /boot/efi
Partition 2: Basic, 1024 MiB, /boot
Logical Drive Label: 027F0A25PDNLH0BRH2386E5FB6
Mirror Group 1:
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 900 GB, OK)
Mirror Group 2:
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 900 GB, OK)
Drive Type: Data
LD Acceleration Method: All disabled